RxCoo
Command
line: RxCoo
Description:
Receive
coordinates from total station
TopoLT
toolbar: ![]()
Menu:
TopoLT » Instrument » Receive coordinates
By using this command you can draw point with coordinates
N,E,Z (X,Y,Z) received through serial port (COM1, COM2, etc.) from an
instrument (total station, field book, PocketPC, etc.).
Communication parameters on serial port will be set in such
way that to correspond to parameters set in instrument.
For instruments that are not defined in instruments list you
can realize by yourself reception and transmission format. You can find
description of the way you can introduce a new instrument at Configuration -
Instrument.
To receive points coordinates from an instrument follow the
next steps:
1. connect instrument to
computer on serial port;
2. select from instruments
list proper instrument;
3. set the same parameters
for serial communication;
4. press button [Receive];
5. using instrument menu
move to data sending mode to PC. While points are received they will be written
in table;
6. after coordinates
receiving press button [Stop receiving].
After finishing receiving points that are written in table
can be drawn. You can find description for points drawing mode at command RapPct.